numDataCopies incorrect in overloaded mode

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: Not specified
    • Resolution: Fixed
    • Affects Version/s: 4.0
    • Fix Version/s: 4.0
    • Component/s: Config UI, Roxie
    • Labels:
      None

      Description

      As far as I can tell, in overloaded mode, numDataCopies is set to 'number of parts held per machine' not 'number of copies of any given part in the cluster'

      Which is going to confuse, at least.

      I suggest that all components ignore the value of this field when in overloaded mode (there is always a single copy of the data, and the number of copies per machine can be deduced from the other settings. Configmgr should then start setting it to 1 (or not setting it) in overloaded mode.