Uploaded image for project: 'HPCC'
  1. HPCC
  2. HPCC-19870

Problems with setting affinity in roxie

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: 7.0.0
    • Component/s: Core Libraries, Roxie
    • Labels:
      None

      Description

      A couple of problems:

      control:setAffinity was reading a bool instead of an int64

      the parallel quick sort code was caching the number of cpus, which caused problems if the affinity was changed after roxie had started.

       

        Attachments

          Activity

            People

            • Assignee:
              ghalliday Gavin Halliday
              Reporter:
              ghalliday Gavin Halliday
            • Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved: