Uploaded image for project: 'HPCC'
  1. HPCC
  2. HPCC-19796

Unable to run workunits in certain scenarios

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: 7.0.0
    • Fix Version/s: 7.0.0
    • Component/s: Security Manager
    • Labels:
    • Environment:
      session based ESP
    • Compatibility:
      Major

      Description

      Once logged into a session based ESP, we no longer keep the user's password around. So when they submit a workunit, the security token no longer contains their password.  A digital signature needs to be created and stored in the workunit which can be verified anywhere we currently verify a username/password. Additionally, when sending the signature to Dali, it should be timestamped to ensure a user did not hijack it and submit it with a malicious workunit