Uploaded image for project: 'HPCC'
  1. HPCC
  2. HPCC-19748

Compile elapsed time looks incorrect

    XMLWordPrintable

Details

    • Bug
    • Status: Resolved
    • Minor
    • Resolution: Fixed
    • 7.0.0
    • 7.0.0
    • eclccserver
    • None

    Description

      Looking at the gantt chart at the top of the timings tab, the compile box overlaps the start of the graph execution.  Looking at the workunit, it looks like the elapsed time is being added twice:

      <Statistic c="eclcc"
       count="2"
       creator="myeclccserver@192.168.86.200"
       kind="TimeElapsed"
       s="compile"
       scope="compile"
       ts="1526987187739413"
       unit="ns"
       value="2191621165"/>