Uploaded image for project: 'HPCC'
  1. HPCC
  2. HPCC-19748

Compile elapsed time looks incorrect

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: 7.0.0
    • Fix Version/s: 7.0.0
    • Component/s: eclccserver
    • Labels:
      None

      Description

      Looking at the gantt chart at the top of the timings tab, the compile box overlaps the start of the graph execution.  Looking at the workunit, it looks like the elapsed time is being added twice:

      <Statistic c="eclcc"
       count="2"
       creator="myeclccserver@192.168.86.200"
       kind="TimeElapsed"
       s="compile"
       scope="compile"
       ts="1526987187739413"
       unit="ns"
       value="2191621165"/>

        Attachments

          Activity

            People

            • Assignee:
              richardkchapman Richard Chapman
              Reporter:
              ghalliday Gavin Halliday
            • Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved: