      Description

      The new IBYTI code assumes that subChannels array is an indicator of priority. But it is not. On node 1, subchannel will be { 0, 1, 1, 0 .... }, on node 2 it will be { 0, 0, 2, 1, 0, ....} and on node n it will be { 0, 2, 0, ... 0, 2 }

       

      This explains why the IbytiNoDelayPrm and IbytiNoDelaySec stats are weird on nodes 1 and 100, but also probably causes the entire new IBYTI logic to be flawed.