Uploaded image for project: 'HPCC'
  1. HPCC
  2. HPCC-18202

Unable to do DFU copy job after QA200 roxie upgraded to OSS 6.4.0-1

    XMLWordPrintable

    Details

      Description

      I upgraded the QA200 roxie (http://10.194.21.114:8010) to OSS 6.4.0-1 on Friday evening, 8/18. We have a user that is now unable to successfully use DFU copy on any of the targets in the environment. WU W20170821-101948 is getting the following errors. There are several other WU examples out there. NO CHANGES were made to the environment.xml file.

      Here is the code he is attempting to run:

      STD.file.copy('~thor_data400::key::vehiclev2::autokey::address_qa'   , 'roxie_qa200',       '~thor_data400::key::vehiclev2::autokey::address_qa'   , '10.194.10.1:7070' , , , ,true , ,true ,, , ,);

      // STD.File.CreateSuperFile('~thor::compid::Audit::key::idl_qa',,1);

      Prior to the upgrade (previously on 6.2.16-1), this process was working. The user reports he is able to use the ECL Watch to do the copy manually. It is just the WUs that are failing. Any ideas?

       

      00000008 2017-08-21 10:19:59.535 12438 12451 "AgentExec: Dequeued workunit request 'W20170821-101948'"

      00000009 2017-08-21 10:19:59.535 12438 12451 "AgentExec: Executing 'start_eclagent WUID=W20170821-101948 DALISERVERS=10.194.21.113:7070'"

      0000000A 2017-08-21 10:19:59.538 12438 12451 "Execution started"

      0000000B 2017-08-21 10:19:59.538 12438 12451 "AgentExec: Waiting on queue(s) 'hthor_dev_qa200.agent,hthor_qa_qa200.agent,hthor_prd_qa200.agent,hthor_ctqa_qa200.agent'"

      00000000 2017-08-21 10:19:59.555 13480 13480 "Logging to /mnt/disk1/var/log/HPCCSystems/eclagent_qa200/eclagent.2017_08_21.log"

      00000001 2017-08-21 10:19:59.565 13480 13480 "ECLAGENT build internal_6.4.0-1"

      00000002 2017-08-21 10:19:59.599 13480 13480 "Waiting for workunit lock"

      00000003 2017-08-21 10:19:59.599 13480 13480 "Obtained workunit lock"

      00000004 2017-08-21 10:19:59.627 13480 13480 "Loading dll (libW20170821-101948.so) from location /var/lib/HPCCSystems/dllserver/temp/libW20170821-101948.so"

      00000005 2017-08-21 10:19:59.628 13480 13480 "Starting process"

      00000006 2017-08-21 10:19:59.628 13480 13480 "RoxieMemMgr: Setting memory limit to 314572800 bytes (1200 pages)"

      00000007 2017-08-21 10:19:59.628 13480 13480 "Transparent huge pages unsupported or disabled by system."

      00000008 2017-08-21 10:19:59.629 13480 13480 "Memory released to OS on each 256k 'page'"

      00000009 2017-08-21 10:19:59.629 13480 13480 "RoxieMemMgr: 1216 Pages successfully allocated for the pool - memsize=318767104 base=0x7f0026f40000 alignment=262144 bitmapSize=38"

      0000000A 2017-08-21 10:19:59.629 13480 13480 "Waiting for run lock"

      0000000B 2017-08-21 10:19:59.629 13480 13480 "Obtained run lock"

      0000000C 2017-08-21 10:19:59.630 13480 13480 "setResultString(gl7,-3,'')"

      0000000D 2017-08-21 10:19:59.630 13480 13480 "Copy:  ~thor_data400::key::vehiclev2::autokey::address_qa as superfile"

      0000000E 2017-08-21 10:19:59.633 13480 13480 "ERROR: -1: Could not find any WS FileSpray in the target HPCC configuration. (in item 1)"

      0000000F 2017-08-21 10:19:59.633 13480 13480 "Releasing run lock"

      00000010 2017-08-21 10:19:59.635 13480 13480 "System error: -1: Could not find any WS FileSpray in the target HPCC configuration."

      00000011 2017-08-21 10:19:59.636 13480 13480 "ERROR: System error: -1: Could not find any WS FileSpray in the target HPCC configuration."

      00000012 2017-08-21 10:19:59.636 13480 13480 "Process complete"

      00000013 2017-08-21 10:19:59.658 13480 13480 "Workunit written complete"