Potential problem in smartjoin if late failover/spilling and constant RHS

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: Not specified
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: 6.4.0
    • Component/s: Thor
    • Labels:
      None

      Description

      If smart join fails over at the last stage and the RHS a flag was not set.
      This had no effect unless the lookupjoin was reused (e.g. in loop) and the RHS was constant. If it had spilt (late) and in a loop and constant RHS, then a crash would ensue because it had failed to re-prepare the RHS.