      Description

      10.241.12.208 thor50_dev03 was up and running, both master and slaves, but all that has been in the log is SYS and DSK tracing.

      W20160810-141518 attempted to run but got aborted with the following in the logs:
      0000000C 2016-08-10 14:15:44.865 5298 5298 "Enqueuing on thor50_dev.thor to run wuid=W20160810-141518, graph=graph1, timelimit=172800 seconds, priority=0"
      0000000D 2016-08-10 14:15:44.871 5298 5298 "Thor on 10.241.12.208:24000 running W20160810-141518"
      0000000E 2016-08-10 14:23:44.888 5298 5305 "Abort detected"
      0000000F 2016-08-10 14:28:44.888 5298 5305 "ERROR: EclAgent failed to abort within 300s - killing process"

      Restarting the thor allowed it to successfully pick up jobs and run to completion.